Sentry 12-Key 2.0 Most Knights Furnaces use the Sentry 12-key. Some of its feature include:
- Temperature Display throughout firing and cooling in your choice of °F or °C
- Firing Cost Enter the cost of electricity and kiln amperage in Options. After the kiln fires to completion, press the 8 key for the cost of electricity to fire that load.
- Rate At the factory, we can configure a controller for you to show rate as degrees of temperature change per hour (the default), degrees of temperature change per minute, or elapsed time needed to reach a temperature.
- Stop/Back Key goes back one step with each key press during programming. Use this feature to correct programming errors.
- Add Time Key adds five minutes to a temperature hold with each key press during firing. Helpful for glass with holds.
- Program Review lets you check that the program you are about to fire is correct.
- Audible Temperature Alarm to remind yourself to close a vented lid or to check the kiln near firing completion.
- Thermocouple Selection The Sentry 2.0 can operate types K, S or R thermocouples.
- Error Messages report mechanical problems such as a disconnected thermocouple, bad voltage, temperature deviation.
- 14 Segment Display is easier to read than the previous 7 segment.
- Program Safety Lock for the program in active memory. Gives you peace of mind.
- Delay Fire Set the time that the firing is to start. The kiln will turn on at that time.
- LED Lights show when the relays are powered.
- Quick Release Molex Connectors permit fast removal of the controller. Replacing the Sentry 2.0 or Sentry Xpress takes only minutes.